Electrical
Specifications - Inverter
|
| Model |
Freedom SW 2012 |
Freedom SW 3012 |
| Output power |
2000 W
(continuous at
30° C) |
3000 W
(continuous at
40° C) |
| Surge Rating (5 seconds) |
4000 W |
6000 W |
| Output current |
17 AAC |
24 AAC |
| Peak output current |
55 AAC |
80 AAC |
| Output frequency |
60 Hz +/- 0.2 Hz |
| Output voltage |
120 VAC |
| Output waveform |
Pure sine wave |
| Optimal efficiency |
90% |
| No-load power draw (inverting) |
< 3 ADC |
| Standby power draw (inverter off) |
< 0.25 ADC |
| Input DC voltage range |
10 - 16 VDC |
| Low battery voltage shutdown cut-off |
10.5 VDC (selectable) |
| High battery voltage shutdown cut-off |
16.5 VDC (selectable) |
| AC connections |
Single phase in / out |
Split phase in / dual out,
Dual in / dual out
|
| |
Electrical
Specifications - Charger
|
| Model |
Freedom SW 2012 |
Freedom SW 3012 |
| Output current (maximum) |
100 ADC |
150 ADC |
| Output voltage |
12 VDC |
| Output voltage range |
3.0 - 16.0 VDC |
| Charge control |
3 stage with manual equalize |
| Charge temperature compensation |
Battery temperature sensor (included) |
| Optimal efficiency |
> 85% |
| AC input power factor (maximum charge) |
> 0.98 |
> 0.95 |
| Input current (for maximum charging) |
15.8 AAC RMS nominal |
22 AAC RMS nominal |
| Input AC voltage |
120 VAC |
| Input AC voltage range |
85 - 140 VAC |
| Dead battery charge |
> 3.0 VDC |
> 3.0 VDC |
| Supported AC input types |
Single input
(up to 30 A) |
Split phase
(up to 30 A per line)
Dual input
(up to 30 A per line) |
| |
General
Specifications
|
| Model |
Freedom SW 2012 |
Freedom SW 3012 |
| Compatible battery types |
Flooded / Gel / AGM |
| Transfer relay rating |
1 leg of 30 A |
2 legs at 30 A each |
Transfer time
(AC to inverter and inverter to AC) |
< 20 ms |
| Cooling |
Fan cooled, temperature controlled |
| Optimal operating temperature range |
-4 to 86 °F (-20 to 30 °C) 1700W @ 60 °C |
-4 to 104°F (-20 to 40 °C) 2600W @ 60 °C |
| Storage ambient temperature range |
-67° F to +167° F
(-55° C to 75° C) |
-40° F to +185° F
(-40° C to 85° C) |
| Humidity (operation/storage) |
≤ 95% RH, non-condensing |
| Altitude (operating) |
15,000 ft (4,572 m) |
| Unit dimensions (H x W x L) |
7.75 x 13.5 x 15.25" (19.7 x 34.3 38.7 cm) |
| Unit weight |
60.5 lbs (27.5 kg) |
69.4 lbs (31.5 kg) |
| Mounting |
Deck or wall mount with fans and DC/AC sides facing sideward |
| Warranty |
2 years |
| Part number |
815-2012 |
815-3012 |
| |
Accessories
|
| Battery temperature sensor |
Part# 808-0946 - Included |
| Freedom Sequence Intelligent Power Mgr. |
Part# 809-0913 - Sold separately |
| Automatic Generator Start (AGS) |
Part# 809-0915 - Sold separately |
| System Control Panel (SCP) |
Part# 809-0921 - Sold separately |
| 3' Network cable for SCP |
Part# 809-0935 - Sold separately |
| 25' Network cable for SCP |
Part# 809-0940 - Sold separately |
| 75' Network cable for SCP |
Part# 809-0942 - Sold separately |
| Freedom SW On/Off remote panel |
Part# 808-9002 - Sold separately |
| GFCI option |
Part# 808-9003 - Sold separately |
| Drip shields |
Part# 808-9004 - Sold separately |
| Stacking cable for series stacking |
Part# 808-9005 - Sold separately |
| |
Regulatory & Environmental Compliance
|
| Safety |
CSA 107.1, UL 458 with marine supplement (when used with drip shield, ABYC E11 - Alternating Current and Direct Current Electrical Systems on Boats, and ABYC A31 - Battery Chargers and Inverters |
| EMC |
FCC Part 15, Class B
Industry of Canada ICES-0003, Class B
|