TEST RESULTS: WAGAN 5000 INVERTER 09-12-2003
Wagan Corporation:
Below are the results of the 5000Watt/ 10000Watt
Wagan Power Inverter. The retest was done using the same batteries
and equipment as in previous test on 12-16-2002. The retest was
conducted using 2 gauge wire as per your factory instructions,
and 3/0 gauge wire.
Metering Equipment: True RMS Fluke 76 Meter and Fluke 41 Meter.
Power Source: (6) Interstate Batteries, Marine/RV deep cycle.
Model# SRM-4D / 1645 CA / 1314 CCA Batteries rated at 25A each for 6.5 hours
Set-up: Batteries (6) wired in parallel using
3/0 cable, capable of 150A.
Two (2) power strips coming out of inverter connecting six (6) 250/500W halogen
lights
Battery to inverter connection:
Retest #1 - 2 gauge
Retest #2 -3/0 gauge
Initial battery reading: 12.1 VDC across all batteries
Initial inverter output reading: 118.3 VAC.
Quick and simple results;
1) As tested with 3/0 wire, inverter had no problem
and no alarms were sounded or indicated.
2) 5000W plus no problems at all. Stopped tested at 5030W as in
previous test (12-16-2002).
3) Testing with 2 gauge wire, volt indicator started to flicker
between green and yellow at 3000W.
4) 3000W, voltage at batteries reading 11.4 VDC and 115.7 VAC
at the inverter outlets. (2 gauge wire)
5) At 5000W / 2 gauge wire, inverter alarm in the yellow. Inverter
output 113.4 VAC and batteries reading 11.2 VDC. All items used to test load on
inverter are operating. Lights did dim when inverter load was increased to 5000W
from 3000W.
The conclusion reached, larger capacity cables enabled the inverter
to handle the advertised specification with no problems. 2 gauge wire was capable
of handling 5000W but only marginally.