Electrical
Specifications - Inverter
|
| Model |
ME 2012 |
ME 2512 |
ME 3112 |
| Input battery voltage range |
9 - 16 VDC |
9 - 16 VDC |
9 - 16 VDC |
| Nominal AC output voltage |
120 VAC |
120 VAC |
120 VAC |
| Output frequency and accuracy |
60 Hz +/- 0.005% |
60 Hz +/- 0.005% |
60 Hz +/- 0.005% |
| 1 msec surge current (amps AC) |
60 |
100 |
120 |
| 100 msec surge current (amps AC) |
37 |
45 |
50 |
| 5 sec surge power (real watts) |
3700 |
5000 |
6000 |
| 30 sec surge power (real watts) |
3450 |
4500 |
4800 |
| 5 min surge power (real watts) |
3100 |
3500 |
3950 |
| 30 min surge power (real watts) |
2400 |
2900 |
3500 |
| Continuous power output at 45° C |
2000 VA |
2500 VA |
3100 VA |
| Rated input battery current |
191.0 ADC |
239.1 ADC |
296.5 ADC |
| Inverter efficiency (peak) |
95% |
91% |
90% |
Transfer time |
16 msecs |
16 msecs |
16 msecs |
Search mode |
0.2 ADC |
0.2 ADC |
0.2 ADC |
| No load (120 VAC output) |
0.87 ADC |
0.95 ADC |
0.97 ADC |
| Waveform |
Modified Sine Wave |
Modified Sine Wave |
Modified Sine Wave |
| |
Electrical
Specifications - Charger
|
| Model |
ME 2012 |
ME 2512 |
ME 3112 |
| Continuous output at 45° C |
100 A DC |
130 A DC |
160 A DC |
| Charger efficiency |
85% |
85% |
85% |
| Power factor |
> .95 |
> .95 |
> .95 |
| Input current at rated output
|
15 AAC |
18 AAC |
21 AAC |
| |
General
Specifications
|
| Model |
ME 2012 |
ME 2512 |
ME 3112 |
| Transfer relay capability |
2 legs at 30 A for 120 V/30 A or 240 V/60A service |
| Five stage charging capability |
Bulk, Absorb, Float, Equalize, and Battery Saver™ |
| Battery temperature compensation |
With available temp sensor (battery temp 0 – 50° C) |
| Remote inverter on/off switch |
With available pigtail to connect to dry contact |
| Internal cooling |
0 to 120 cfm variable speed drive using dual 92mm brushless DC fans |
| Overcurrent protection |
Yes, with two overlapping circuits |
| Overtemperature protection |
Yes on transformer, MOSFETS, and battery |
| Conformal coating on PCB’s for corrosion protection |
Yes |
| Powder coated chassis & top for corrosion protection |
Yes |
| Stainless steel fasteners for corrosion protection |
Yes |
| Dual AC branch rated output breakers |
Optional on the ME2012 - 20 amp rated AC breakers |
| Listings |
ETL Listed to UL/cUL 458, CSA C22.2 #107.1-01 |
| Warranty |
Three (3) years |
| |
|
Environmental
Specifications
|
| Model |
ME 2012 |
ME 2512 |
ME 3112 |
| Operating temperature |
-20° C to +60° C (-4° F to 140° F) |
| Nonoperating temperature |
-40° C to +70° C (-40° F to 158° F) |
| Operating humidity |
0 to 95% RH non condensing |
| |
|
Physical
Specifications
|
| Model |
ME 2012 |
ME 2512 |
ME 3112 |
| Dimensions (H x W x D) |
13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm) |
| Mounting |
Shelf (top or bottom up) or bulkhead (vents up) |
| Weight |
38 lb (17 kg) |
42 lb (19 kg) |
45 lb (20 kg) |
| Max operating altitude |
15,000’ (4570 m) |